首页>>客户服务>>服务器技术问答>>IBM服务器疑难解答:x3550 FRU号


System service parts - IBM System x3550
Applicable countries and regions
See ServerProven for all parts that are compatible with this system.

Move the pointer over the part for a description. Click the part to locate the part number.

x3550_partsdiagram.gif Top cover assemblyHeatsink assemblyAir bafflesMemoryServeRAID 8kPCI-X riser cardPCI Express riser cardPlanarPower supplyPower supply filler panelChassis assemblyFan assembly unitCD-RW/DVD combo driveOperator information panel assemblyHot-swap filler panelHard disk driveHot-swap SAS hard disk drive cageHot-swap SAS hard disk drive backplanePower backplaneHot-swap filler panelSimple-swap filler panelHard disk driveHard disk driveDisk drive cage, 3.5-inchBackplane SASSATA power cable

Notes:

  1. If your specific model is not listed, use the Quick path feature on the right-nav and refer to the product description. Look for the "Based on" model.
  2. Field Replacement Units (FRU) that are identified in the CRU column by 1 or 2 are Customer Replaceable Units.
    • Each FRU is available for all types or model, unless specific types or models are specified.
    • A CRU (Customer Replaceable Units) is identified 1 or 2 in the CRU ID column. 1 means that the part is a Tier 1 CRU; 2 means that the part is a Tier 2 CRU. An N in the CRU ID column means that the part is not a CRU.
      • Tier 1 CRU:
        • No tools required.
        • A coin or a thumb screw is acceptable.
        • Minimal technical expertise is required.
        • Minimal problem determination is required-less than 5 minutes.
      • Tier 2 CRU:
        • Up to 4 screws or fasteners have to be removed.
        • Some technical experience is required.
        • IBM Support Center assistance may be used.
        • Problem determination can be done by customer, either on site or with IBM Support Center assistance.
Index Description Replacement part number (FRU) CRU/FRU
1 Top cover
(all models) 43W0609 1
2 Heatsink
(all models) 39Y9423 N
3 Air baffles
(all models) 39Y9420 1
4 Memory
512 MB PC2-5300 ECC (all except models A2x, C1x, C2x, C3x, C4x, CBx, CCx, CDx, JAx, JBx) 39M5781 1
1 GB PC2-5300 ECC (models A2x, B1x, B3x, B4x, B5x, B6x, B7x, BAx, BCx, BDx, BEx, BFx, BGx, C1x, C2x, C3x, C4x, CBx, CCx, CDx, JAx, JBx, LBx, MAx) 39M5784 1
2 GB PC2-5300 ECC (optional) 39M5790 1
4 GB PC2-5300 ECC (optional) 41Y2845 1
4 GB PC2-5300-555 ECC (optional) 44E4402 1
5 ServeRAID
ServeRAID 8 with battery card (optional) 25R8076 1
ServeRAID 8 k-l card (all except models 46x, G6x) 25R8079 1
6 PCI-X riser card
(optional) 39Y9545 2
7 PCI Express riser card
(all models) 32R2883 2
8 System board, Planar
SATA (modesl 22x, 32x, 42x, 46x, G6x) 43W5900 N
SAS (models 21x, 31x, 3Ax, 41x, 45x, 4Ax, 4Sx, 51x, 5Ax, 61x, 6Ax, 71x, 7Ax, A1x, A2x, B1x, BAx, B3x, B4x, B5x, B6x, B7x, B9x, BCx, BDx, BEx, BFx, BGx, BJx, C1x, C2x, C3x, C4x, CBx, CDx, G5x, JAx, JBx, L2x, LBx, M1x, MAx) 44E5082 N
SATA (model CCx) 44E5124 N
SAS (optional) 44E5085 N
9 Power supply
AC 670 W (all models) 39Y7189 1
DC -48 V (optional) 39Y7186 1
AC 450 W (optional) 39Y7196 1
10 Power supply filler panel
(all models) 39Y9420 1
11 Chassis
(all models) 39Y9522 N
12 Fan
Dual-fans (all models) 26K8083 1
13
CD-RW/DVD combo drive
24/24/8/24X HLDS Slim UltraBay Enhanced (all models) 39M3541 1
14 Operator information panel
(all models) 43W0625 N
15 Hot-swap filler panel
2.5-inch (models 4Sx, BAx, BCx, BDx, BEx, BFx, BGx, BJx, CBx, CDx, JAx, JBx, LBx, MAx) 26K8680 1
16 Hard drive
2.5-inch hot-swap (all models) varies 1
17 Hot-swap SAS hard drive cage
2.5-inch (models 4Sx, BAx, BCx, BDx, BEx, BFx, BGx, BJx, CBx, CDx, JAx, JBx, LBx, MAx) 32R2822 2
18 Hot-swap SAS hard disk drive backplane
2.5-inch (model 4Sx) 39Y9541 2
19 Power backplane
(all models) 39Y6972 2
20 Hot-swap filler panel
3.5-inch (models 45x, A1x, A2x, C1x, C2x, C3x, C4x, B1x, B3x, B4x, B5x, B6x, B7x, B9x, G5x, L2x, M1x) 39M4375 1
21 Simple-swap filler panel
3.5-inch (models 46x, G6x) 39M4343 1
22 Hard drive
3.5-inch SATA (all models) varies 1
23 Hard drive
3.5-inch SAS hot-swap (all models) varies 1
24 Disk drive cage
3.5-inch SATA Simple-swap (models 46x, CCx, G6x) 32R2823 2
3.5-inch SAS hot-swap (models 45x, A1x, A2x, C1x, C2x, C3x, C4x, B1x, B3x, B4x, B5x, B6x, B7x, B9x, G5x, L2x, M1x) 32R2821 2
25 Backplane SAS
3.5-inch (models 45x, A1x, A2x, C1x, C2x, C3x, C4x, CBx, CCx, CDx, BAx, BCx, BDx, BEx, BFx, BGx, G5x, JAx, JBx, LBx, MAx) 39M4349 2
26 SATA power cable
With backplate (models 46x, G6x) 26K8060 1
. Alcohol wipe
(all models) 59P4739 N
. 3.0 V ServeRAID 8 k battery pack
(optional) 25R8088 1
. 3.0 V battery
System board (all models) 33F8354 1
. Cables
Cable, 6 inch video (optional) 39Y9493 2
Cable, 6 inch serial (optional) 39Y9495 2
Cable, -48 V power supply (optional) 43W0619 N
Cable, front panel USB 26K8058 2
Cable, power, SAS (models 45x, 4Sx, A1x, A2x, BAx, BCx, BDx, BEx, BFx, BGx, C1x, C2x, C3x, C4x, CBx, CCx, CDx, G5x, JAx, JBx, LBx, MAx) 26K8068 2
Cable, signal, SAS HDD (models 45x, 4Sx, A1x, A2x, BAx, BCx, BDx, BEx, BFx, BGx, C1x, C2x, C3x, C4x, CBx, CCx, CDx, G5x, JAx, JBx, LBx, MAx) 42C2376 2
Rack power (all models) 39M5377 1
. Cable management arm assembly
1U (all models except 45X, 46X, 4SX) 39Y9530 1
. CD-RW/DVD-ROM drive interposer card
(all models) 42C3983 2
. DVD filler
(optional) 41Y8740 1
. Hard drive
1.0 TB 72000 (optional) 43W7629 1
300 GB 15000 rpm hot-swap SAS (optional) 43X0805 1
750 GB hot-swap SATA 7200 rpm, 3.0 GB (optional) 43W7579 1
146.8 GB 10000 rpm SFF hot-swap 43X0825 1
73 GB 1000 rpm SFF hot-swap SAS (optional) 43X0839 1
. 3U SCSI adapter
(optional) 43W4325 2
. Line cord
2.8M 10A (all models) 39M5081 1
. Low-profile adapter
(all models) varies 1
. Media bezel
(all models) includes front video 39Y9507 2
. Microprocessor
Dual-Core 1.6 GHz/1066 MHz (2 x 2 MB L2 cache) with heatsink (models 21x, 22x) 42C4231 N
Quad-Core 1.6 GHz/1066 MHz (8 MB L2 cache) with heatsink (model A1x) 42D3803 N
Quad-Core 1.0 GHz/1066 MHz (8 MB L2 cache) with heat sink (model JAx) 42D3872 N
Dual Core 1.86 GHz/1066 MHz (6 MB L2 cache) without heat sink (models M1x, MAx) 44E5145 N
Dual-Core 1.86 GHz/1066 MHz (2 x 2 MB L2 cache) with heatsink (models 31x, 32x, 3Ax) 42C4230 N
Quad-Core E5320 1.86 GHz/1066 MHz (8 MB L2 cache) with heatsink (model C1x) 42D3799 N
Quad-Core 1.86 GHz/1066 MHz (8 MB L2 cache) with heat sink (model JBx) 43W5908 N
Dual-Core 2.0 GHz/1333 MHz (2 x 2 MB L2 cache) with heatsink (models 41x, 42x, 4Ax) 42C4229 N
Dual-Core 2.33 GHz/1333 MHz (2 x 2 MB L2 cache) with heatsink (models 51x, 5Ax) 42C4228 N
Dual-Core 2.33 GHz with heatsink (optional) 42D3771 N
Dual-Core 2.66 GHz/1333 MHz (2 x 2 MB L2 cache), with heatsink (models 61x, 6Ax) 42C4227 N
Dual-Core 3.0 GHz/1333 MHz (2 x 2 MB L2 cache) with heatsink (models 71x, 7Ax) 42C4226 N
Quad-Core 3.0 GHz/1333 MHz (8 MB L2 cache) with heat sink (models C4x, CDx) 44E5039 N
Dual-Core 3.0 GHz/667 MHz (2 x 2 MB L2 cache) with heatsink (models G5x, G6x) 42C4001 N
Dual-Core3.73 GHz/1067 MHz (2 x 2 MB L2 cache) with heatsink (models 45x, 46x, 4Sx) 42C3998 N
Quad-Core E5335 2.0 GHz/1333 MHz (8 MB L2 cache) with heatsink (model A2x) 42D3801 N
Quad-Core E5345 2.33 GHz/1333 MHz (8 MB L2 cache) with heatsink (models C2x, CBx) 42D3800 N
Quad-Core X5355 2.66 GHz/1333 MHz (8 MB L2 cache) with heatsink (models CCx, C3x) 42D3802 N
Quad-Core 2.00 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (models BAx, B1x) 44R5644 N
Quad-Core 2.50 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (models BCx, B3x) 44R5646 N
Quad-Core 2.50 GHz/1333 MHz (12MB L2 cache) 50W, without heat sink (models L2x LBx) 44E5144 N
Quad-Core 2.66 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (models BDx, B4x) 44R5647 N
Quad-Core 2.83 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (models BEx, B5x) 44R5648 N
Quad-Core 3.0 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (models BFx, B6x) 44R5649 N
Quad-Core 3.16 GHz/1333 MHz (12 MB L2 cache) 120W, without heat sink (models BGx, B7x) 44E5066 N
Quad-Core 3.00 GHz/1333 MHz (12 MB L2 cache) 120W, without heat sink (models B9x, BJx) 44E5117 N
Quad-Core 2.33 GHz/1333 MHz (12 MB L2 cache) 80W, without heat sink (optional) 44R5645 N
. Miscellaneous parts kit
(all models) 26K8080 2
. Optical interposer card
(all models) 42C3983 2
. QLogic iSCSI single-port PCIe adapter
(optional) 39Y6148 1
. QLogic iSCSI dual-port PCIe adapter
(optional) 42C1772 1
. Server adapter
PRO/1000 PF (optional) 42C1752 1
PRO/1000 PT quad port server adapter (optional) 39Y6138 1
10 GB PCIe SR (optional) 42C1762 1
. Service label
(models 45x, 4Sx, A1x, A2x, BAx, BCx, BDx, BEx, BFx, BGx, C1x, C2x, C3x, C4x, CBx, CCx, CDx, G5x, JAx, JBx, LBx, MAx) 43W0610 1
3.5-inch SATA (models 46x, G6x) 32R2820 1
CRU/FRU (all models) 43V4869 1
Right fan door (all models) 39Y9418 1
. Slide kit
(all models except 45x, 46x, 4Sx) 39Y9510 2
. Thermal grease kit
(all models) 41Y9292 N
. Toolless rail kit
models (45X, 4SX, 46X) 43V5369 2
. Y jumper cord
(optional) 39M5450 1

, TD>

 